Engineering Drawing - Current Monitor - Style C

AC Applications

  
Model Number
Output
Sensitivity
 

Volts/Amp
Hole
Dia.

 inch
Max.
Peak Current
 kA
Max.
RMS
Current
 
A
Low Frequency
3 dB Point
 
Hz
High Frequency
3 dB Point
MHz
Saturation
Peak A/Hz
As
CM-100-C
1
3.5
0.5
30
30
20
0.08
CM-10-C
0.1
3.5
5
250
0.6
10
6
CM-1-C
0.01
3.5
50
1,000
0.03
3.5
59
CM-01-C
0.001
3.5
500
1400
0.004
0.5
140

Pulse Applications

 
Model Number

Output
Sensitivity

Volts/ Amp

Hole
Diameter

inch

Max. Peak Current

kA

Droop


%/ms

Usable
Risetime

Nano-seconds

Saturation
No Bias

∫idt
As

Saturation
With Bias

∫idt
As

CM-100-C

1

3.5

0.5

20

17.5

0.008

0.025

CM-10-C

0.1

3.5

5

0.3

35

0.2

2.0

CM-1-C

0.01

3.5

50

0.02

100

2.2

15

CM-01-C

0.001

3.5

500

0.003

700

10

40